Intro
So we got a house that has a Heat Pump, all cool and dandy. Then you start to use it on the daily basis and you start to understand how it works, what the operation means for you when you taking a shower.
Suddenly, at some time of the day you may be talking a shower and then COLD WATER gushes down... your reservoir of hot water didn't had time to replenish and then the temperature starts to go down.
Then we learned the tricks and the do's and do nots. But for the most amount of things you can do to organize the daily life and use the heat pump in the "correct" way , you will still miss some.
The NIBE as a company, does a good job on the equipment but a bad job in user experience.
The problem that needs a solution
If you are preparing to go to the shower, you can go from the living room upstairs and have a look on the digital display, and you will get some info:

But then if you are at the shower, or just going to the bathroom to take a shower, you need to know what is the status of the heat pump.
For such I have developed a multi-part project that is under development, as I write this I am on the third phase, still need a last part to accomplish.
So the first one, is to create a method to read the information from the heat pump and for that I could use the developer website from NIBE , where, I can connect the heat pump to the internet and then read information from there.
Then I developed first a reader in Golang, which also provides information in detail about the data extracted from the heat pump.
Following this entry on the blog, you will find the README from the repository that I have publicly exposed.
The repository is here: https://git.juliochegedus.com/spectronet/nibe-reader
This project is divided in these parts in my head:
- Part 1: Create a reader that users the myUplink from NIBE, gather information about the heat pump (this blog entry)
- Part 2: Use this app to display information in an LCD via a Raspberry Pi on the Bathroom (that also requires to solder an LCD and build a 3D print STL for the RPI + LCD -- this is another entry on this blog)
- Part 3: The more daring and final part, is to add a humidity sensor to the setup and a 868Mhz radio signaler to turn on the ventilation on demand tomatically
nibe-reader
Go service that polls the myUplink API for NIBE heat pump data and writes it to local JSON files.
What it does
- Authenticates with myUplink using OAuth2 client credentials
- Fetches all device data points every minute (configurable)
- Saves points as JSON to
logs/points_<systemID>_<deviceID>.json, overwriting on each poll - Saves system/device info once at startup to
logs/systems.json - Renews the auth token every 55 minutes (configurable)
Requirements
- Go 1.24+
- A myUplink developer account with a registered application (client credentials flow)
Register at dev.myuplink.com to get a client ID and secret.
Build
go build -o nibe-reader ./nibe.goConfiguration
All configuration is via environment variables:
| Variable | Required | Default | Description |
|---|---|---|---|
MYUPLINK_CLIENT_ID |
yes | — | OAuth2 client ID |
MYUPLINK_CLIENT_SECRET |
yes | — | OAuth2 client secret |
TOKEN_RENEWAL_INTERVAL_MINUTES |
no | 55 |
Token refresh interval |
DATA_COLLECTION_INTERVAL_MINUTES |
no | 1 |
Points polling interval |
Run
export MYUPLINK_CLIENT_ID=your-client-id
export MYUPLINK_CLIENT_SECRET=your-client-secret
./nibe-readerData is written to logs/ (created automatically).
Utilities
list-parameters
Reads the most recently written points file and prints all available parameter names, IDs, and current values.
go run list-parameters.go
go run list-parameters.go -dir logs -output params.txtlist-parameters results:
# ./list-parameters
Using most recent file: logs/points.json
Available Parameters:
====================
Parameter: - of which hot water:
ID: 44135
Current Value: 3035
Parameter: Average outdoor temp (BT1)
ID: 40067
Current Value: 26
Parameter: Brine in (BT10)
ID: 40015
Current Value: 13.2
Parameter: Brine out (BT11)
ID: 40016
Current Value: 8.4
Parameter: Brine pump speed (GP2)
ID: 43439
Current Value: 100
Parameter: Calculated cooling supply climate system 1
ID: 44270
Current Value: 19.8
Parameter: Calculated supply climate system 1
ID: 43009
Current Value: 20
Parameter: Condenser (BT12)
ID: 40017
Current Value: 53
Parameter: Cooling offset climate system 1
ID: 48739
Current Value: 0
Parameter: Current (BE1)
ID: 40083
Current Value: 0.1
Parameter: Current (BE2)
ID: 40081
Current Value: 0.1
Parameter: Current (BE3)
ID: 40079
Current Value: 0.1
Parameter: Current compressor frequency
ID: 41778
Current Value: 90
Parameter: Current hot water mode
ID: 43109
Current Value: 2
Parameter: Current temperature system 1
ID: 50225
Current Value: -32768
Parameter: Degree minutes
ID: 40941
Current Value: 0
Parameter: Discharge (BT14)
ID: 40018
Current Value: 86.4
Parameter: Est. power at DOT
ID: 42108
Current Value: 3181
Parameter: Extern. adjustment climate system 1
ID: 43161
Current Value: 0
Enum Values:
- 0: Off
- 1: On
Parameter: Extern. blocking input cooling
ID: 43152
Current Value: 0
Enum Values:
- 0: Off
- 1: On
Parameter: Heating medium pump speed (GP1)
ID: 43437
Current Value: 59
Parameter: Hot water amount
ID: 50345
Current Value: 19
Parameter: Hot water boost
ID: 48132
Current Value: 0
Enum Values:
- 0: Off
- 4: One-time incr.
- 1: 3 hr
- 2: 6 hr
- 3: 12 hr
Parameter: Hot water charging (BT6)
ID: 40014
Current Value: 40.5
Parameter: Hot water offset (Smart Price Adaption)
ID: 44897
Current Value: 20
Parameter: Hot water temp.
ID: 50325
Current Value: 49
Parameter: Hot water top (BT7)
ID: 40013
Current Value: 49.2
Parameter: Int elec add heat
ID: 49993
Current Value: 4
Enum Values:
- 0: Alarm
- 1: Alarm
- 2: Active
- 3: Off
- 4: Blocked
- 5: Off
- 6: Active
Parameter: Inverter temperature
ID: 43140
Current Value: 56.8
Parameter: Liquid line (BT15)
ID: 40019
Current Value: 45.9
Parameter: Max compressor frequency
ID: 43123
Current Value: 90
Parameter: Min compressor frequency
ID: 43122
Current Value: 20
Parameter: Next periodic increase: 27 . 05 . 2026
ID: 50249
Current Value: 3
Parameter: Number of compressor starts
ID: 43416
Current Value: 6314
Parameter: Offset
ID: 47011
Current Value: 0
Parameter: Oil temperature (BT29)
ID: 40146
Current Value: 0
Parameter: Oil temperature (EP15-BT29)
ID: 40145
Current Value: 0
Parameter: Oper. time
ID: 43420
Current Value: 17226
Parameter: Oper. time hot water
ID: 43424
Current Value: 3035
Parameter: Outdoor temperature
ID: 40004
Current Value: 25
Parameter: Power internal add. heat
ID: 43084
Current Value: 0
Parameter: Priority
ID: 49994
Current Value: 20
Enum Values:
- 10: Off
- 20: Hot water
- 30: Heating
- 40: Pool
- 41: Pool 2
- 50: Transfer
- 60: Cooling
Parameter: Pump: Brine (GP2)
ID: 50203
Current Value: 1
Enum Values:
- 0: Off
- 1: On
Parameter: Pump: Heating medium (GP1)
ID: 49995
Current Value: 1
Enum Values:
- 0: Off
- 1: On
Parameter: Return line (BT3)
ID: 40012
Current Value: 45.7
Parameter: Room sensor set point value cooling climate system 1
ID: 48785
Current Value: 26
Parameter: Room sensor set point value heating climate system 1
ID: 47398
Current Value: 22
Parameter: Room temperature (BT50)
ID: 40033
Current Value: 26.2
Parameter: Set point value temp system 1, cooling
ID: 50241
Current Value: 0
Parameter: Set point value temp system 1, heat
ID: 50233
Current Value: -32768
Parameter: Smart Control
ID: 50320
Current Value: 0
Enum Values:
- 0: off
- 1: on
Parameter: Status compressor
ID: 43427
Current Value: 60
Enum Values:
- 20: Off
- 40: Starting
- 60: Operating
- 100: Stopping
Parameter: Suction gas (BT17)
ID: 40022
Current Value: 15.9
Parameter: Supply line (BT2)
ID: 40008
Current Value: 52.5
Parameter: Temporary lux
ID: 50004
Current Value: 0
Enum Values:
- 0: off
- 1: on
Parameter: Text not found: id[], fw[nibe-e10], lang[en-US]
ID: 65535
Current Value: 0
Parameter: Time factor add heat
ID: 43081
Current Value: 542.5
Parameter: Used power at DOT
ID: 45434
Current Value: 3181
Parameter: activated
ID: 48442
Current Value: 0
Parameter: alarm room sens cool
ID: 49903
Current Value: 1
Parameter: change in curve
ID: 47028
Current Value: 0
Parameter: climate system
ID: 49715
Current Value: 20
Parameter: comfort mode
ID: 47041
Current Value: 4
Enum Values:
- 0: 0
Parameter: control room sensor syst
ID: 47394
Current Value: 1
Parameter: cool at room over temp.
ID: 47337
Current Value: 2
Parameter: cool/heat sensor
ID: 47340
Current Value: 10
Enum Values:
- 0: none
- 2: BT50
- 10: RMU-BT50
Parameter: cooling curve
ID: 48731
Current Value: 0
Parameter: cooling factor system
ID: 48793
Current Value: 1
Parameter: current value
ID: 40940
Current Value: 0
Parameter: dT Inverter - exh air (BT20)
ID: 43146
Current Value: 0
Parameter: diff. between additional steps
ID: 47209
Current Value: 100
Parameter: filtering time
ID: 47377
Current Value: 2
Parameter: flow line temp. at -10 °C
ID: 47024
Current Value: 35
Parameter: flow line temp. at -20 °C
ID: 47025
Current Value: 40
Parameter: flow line temp. at -30 °C
ID: 47026
Current Value: 45
Parameter: flow line temp. at 0 °C
ID: 48742
Current Value: 20
Parameter: flow line temp. at 10 °C
ID: 48741
Current Value: 20
Parameter: flow line temp. at 20 °C
ID: 48181
Current Value: 20
Parameter: flow line temp. at 30 °C
ID: 48740
Current Value: 20
Parameter: flow line temp. at 40 °C
ID: 48185
Current Value: 20
Parameter: heat at room under temp.
ID: 47336
Current Value: 1
Parameter: heating curve
ID: 47007
Current Value: 6
Parameter: heating factor system
ID: 47402
Current Value: 2
Parameter: number of starts:
ID: 44131
Current Value: 6314
Parameter: op. mode
ID: 47137
Current Value: 0
Enum Values:
- 0: auto
- 1: manual
- 2: add. heat only
Parameter: outdoor temp. point
ID: 47027
Current Value: 0
Parameter: period
ID: 47051
Current Value: 15
Parameter: set max electrical add.
ID: 47212
Current Value: 500
Enum Values:
- 0: 0.0 kW
- 50: 0.50 kW
- 100: 1.0 kW
- 150: 1.50 kW
- 200: 2.0 kW
- 250: 2.50 kW
- 300: 3.0 kW
- 350: 3.50 kW
- 400: 4.0 kW
- 450: 4.50 kW
- 500: 5.0 kW
- 550: 5.50 kW
- 600: 6.0 kW
- 650: 6.50 kW
Parameter: set pt value cool/heat sensor
ID: 48074
Current Value: 21
Parameter: start compressor
ID: 47206
Current Value: -60
Parameter: start cooling
ID: 47374
Current Value: 25
Parameter: start diff additional heat
ID: 48072
Current Value: 400
Parameter: start time
ID: 49909
Current Value: 0
Parameter: status:
ID: 50113
Current Value: 1512
Enum Values:
- 15000: Starting
- 15001: Operating
- 15002: Stopping
- 15003: Off
- 15004: Hot water
- 15005: Heating
- 15006: Pool
- 15007: Cooling
- 15008: Transfer
- 10480: incomp. hp
- 10065: Comm.fault In
- 10066: Communication fault with PCA Input.
- 10067: Communication fault with PCA Input.
- 10068: Com.flt Base
- 10069: Communication fault with PCA Base.
- 10070: Communication fault with PCA Base.
- 10162: Sens flt:BT18
- 15971: incomp. inv.
- 10177: Sens flt:BT14
- 10071: HP alarm
- 10072: High pressure alarm
- 10073: High pressure alarm
- 10074: LP alarm
- 10075: Low pressure alarm
- 10076: Low pressure alarm
- 10077: Comm.flt MC
- 10078: Comm.flt with PCA Motor Controller
- 10079: Communication fault with PCA Motor Controller.
- 10080: MP alarm
- 10081: Motor protection alarm
- 10082: Motor protection alarm
- 10083: Sensor flt:BT1
- 10084: Sensor fault: BT1 outdoor sensor
- 10085: Sensor fault: BT1 outdoor sensor
- 10086: Sensor flt:BT2
- 10087: Sensor fault: BT2 flow line sensor 1
- 10088: Sensor fault: BT2 flow line sensor 1
- 10089: Sens flt:BT12
- 10090: Sensor fault: BT12 condenser out
- 10091: Sensor fault: BT12 condenser out
- 10092: Sensor flt:BT3
- 10095: Sensor flt:BT6
- 10154: internal electrical addition
- 10183: L exh.temp
- 10203: Sensor flt:BT7
- 10187: Defrosting
- 15117: blocked
- 16528: Inverter fault
- 10068: Com.flt Base
- 10311: Inverter I
- 10314: Inverter II
- 10317: Inverter III
- 10110: Hot gas alarm
- 10116: TB alarm
- 10122: Hi cond. out
- 10276: Err: BT63
- 10293: serial no
- 10296: software
- 11176: comm.err hp
- 15117: blocked
- 15629: ext control
- 15701: Preheat
- 15966: Pres.alarm
- 15971: incomp. inv.
- 16537: Soft-start flt
- 16659: Acc. block.
- 15468: initiating
- 11165: pool 2
- 11174: com.err.slave
- 15985: Com.flt GP12
- 16541: not docked
Parameter: stop additional heat
ID: 47376
Current Value: 2
Parameter: stop heating
ID: 47375
Current Value: 20
Parameter: time betw. switch heat/cool
ID: 47335
Current Value: 2
Parameter: total operating time:
ID: 44133
Current Value: 17226Log points file:
# cat points.json
[
{
"category": "F1255-6 R PC",
"parameterId": "40004",
"parameterName": "Outdoor temperature",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T16:59:19+00:00",
"value": 25.0,
"strVal": "25°C",
"smartHomeCategories": [
"sh-outdoorTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40008",
"parameterName": "Supply line (BT2)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:33+00:00",
"value": 52.5,
"strVal": "52.5°C",
"smartHomeCategories": [
"sh-supplyTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40012",
"parameterName": "Return line (BT3)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:31+00:00",
"value": 45.7,
"strVal": "45.7°C",
"smartHomeCategories": [
"sh-returnTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40013",
"parameterName": "Hot water top (BT7)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:04:04+00:00",
"value": 49.2,
"strVal": "49.2°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40014",
"parameterName": "Hot water charging (BT6)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:37+00:00",
"value": 40.5,
"strVal": "40.5°C",
"smartHomeCategories": [
"sh-hwTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40015",
"parameterName": "Brine in (BT10)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T12:44:39+00:00",
"value": 13.2,
"strVal": "13.2°C",
"smartHomeCategories": [
"sh-returnTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40016",
"parameterName": "Brine out (BT11)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:13:20+00:00",
"value": 8.4,
"strVal": "8.4°C",
"smartHomeCategories": [
"sh-supplyTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40017",
"parameterName": "Condenser (BT12)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:07+00:00",
"value": 53.0,
"strVal": "53°C",
"smartHomeCategories": [
"sh-supplyTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40018",
"parameterName": "Discharge (BT14)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:45+00:00",
"value": 86.4,
"strVal": "86.4°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40019",
"parameterName": "Liquid line (BT15)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:43+00:00",
"value": 45.9,
"strVal": "45.9°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40022",
"parameterName": "Suction gas (BT17)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:13:42+00:00",
"value": 15.9,
"strVal": "15.9°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40033",
"parameterName": "Room temperature (BT50)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T15:23:37+00:00",
"value": 26.2,
"strVal": "26.2°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40067",
"parameterName": "Average outdoor temp (BT1)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:16+00:00",
"value": 26.0,
"strVal": "26°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40079",
"parameterName": "Current (BE3)",
"parameterUnit": "A",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.1,
"strVal": "0.1A",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40081",
"parameterName": "Current (BE2)",
"parameterUnit": "A",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.1,
"strVal": "0.1A",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40083",
"parameterName": "Current (BE1)",
"parameterUnit": "A",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.1,
"strVal": "0.1A",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40145",
"parameterName": "Oil temperature (EP15-BT29)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40146",
"parameterName": "Oil temperature (BT29)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40940",
"parameterName": "current value",
"parameterUnit": "DM",
"writable": true,
"timestamp": "2026-05-24T06:09:02+00:00",
"value": 0.0,
"strVal": "0DM",
"smartHomeCategories": [],
"minValue": -3000.0,
"maxValue": 3000.0,
"stepValue": 10.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "40941",
"parameterName": "Degree minutes",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T06:09:02+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "41778",
"parameterName": "Current compressor frequency",
"parameterUnit": "Hz",
"writable": false,
"timestamp": "2026-05-24T17:11:28+00:00",
"value": 90.0,
"strVal": "90Hz",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "42108",
"parameterName": "Est. power at DOT",
"parameterUnit": "W",
"writable": false,
"timestamp": "2026-05-22T16:25:44+00:00",
"value": 3181.0,
"strVal": "3181W",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 1.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43009",
"parameterName": "Calculated supply climate system 1",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-22T04:52:47+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [
"sh-supplyTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43081",
"parameterName": "Time factor add heat",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-23T18:00:40+00:00",
"value": 542.5,
"strVal": "542.5",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43084",
"parameterName": "Power internal add. heat",
"parameterUnit": "kW",
"writable": false,
"timestamp": "2026-05-23T18:06:04+00:00",
"value": 0.0,
"strVal": "0kW",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.01,
"enumValues": [],
"scaleValue": "0.01",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43109",
"parameterName": "Current hot water mode",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:00+00:00",
"value": 2.0,
"strVal": "2",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43122",
"parameterName": "Min compressor frequency",
"parameterUnit": "Hz",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 20.0,
"strVal": "20Hz",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43123",
"parameterName": "Max compressor frequency",
"parameterUnit": "Hz",
"writable": false,
"timestamp": "2026-05-24T17:03:23+00:00",
"value": 90.0,
"strVal": "90Hz",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43140",
"parameterName": "Inverter temperature",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:33+00:00",
"value": 56.8,
"strVal": "56.8°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43146",
"parameterName": "dT Inverter - exh air (BT20)",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "Built-in pass. cooling",
"parameterId": "43152",
"parameterName": "Extern. blocking input cooling",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "Off",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Off",
"icon": ""
},
{
"value": "1",
"text": "On",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43161",
"parameterName": "Extern. adjustment climate system 1",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "Off",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Off",
"icon": ""
},
{
"value": "1",
"text": "On",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43239",
"parameterName": "- of which hot water:",
"parameterUnit": "hrs",
"writable": false,
"timestamp": "2026-05-23T18:05:00+00:00",
"value": 500.0,
"strVal": "500hrs",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43416",
"parameterName": "Number of compressor starts",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:21+00:00",
"value": 6314.0,
"strVal": "6314",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43420",
"parameterName": "Oper. time",
"parameterUnit": "h",
"writable": false,
"timestamp": "2026-05-24T17:11:34+00:00",
"value": 17226.0,
"strVal": "17226h",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43424",
"parameterName": "Oper. time hot water",
"parameterUnit": "h",
"writable": false,
"timestamp": "2026-05-23T17:27:51+00:00",
"value": 3035.0,
"strVal": "3035h",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43427",
"parameterName": "Status compressor",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:21+00:00",
"value": 60.0,
"strVal": "Operating",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "20",
"text": "Off",
"icon": ""
},
{
"value": "40",
"text": "Starting",
"icon": ""
},
{
"value": "60",
"text": "Operating",
"icon": ""
},
{
"value": "100",
"text": "Stopping",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43437",
"parameterName": "Heating medium pump speed (GP1)",
"parameterUnit": "%",
"writable": false,
"timestamp": "2026-05-24T17:11:08+00:00",
"value": 59.0,
"strVal": "59%",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "43439",
"parameterName": "Brine pump speed (GP2)",
"parameterUnit": "%",
"writable": false,
"timestamp": "2026-05-24T17:00:00+00:00",
"value": 100.0,
"strVal": "100%",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "44131",
"parameterName": "number of starts:",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:22+00:00",
"value": 6314.0,
"strVal": "6314",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "44133",
"parameterName": "total operating time:",
"parameterUnit": "hrs",
"writable": false,
"timestamp": "2026-05-24T17:11:35+00:00",
"value": 17226.0,
"strVal": "17226hrs",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "44135",
"parameterName": "- of which hot water:",
"parameterUnit": "hrs",
"writable": false,
"timestamp": "2026-05-23T17:27:52+00:00",
"value": 3035.0,
"strVal": "3035hrs",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "Built-in pass. cooling",
"parameterId": "44270",
"parameterName": "Calculated cooling supply climate system 1",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T16:36:35+00:00",
"value": 19.8,
"strVal": "19.8°C",
"smartHomeCategories": [
"sh-supplyTemp"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "44897",
"parameterName": "Hot water offset (Smart Price Adaption)",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:00+00:00",
"value": 20.0,
"strVal": "20",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "45434",
"parameterName": "Used power at DOT",
"parameterUnit": "W",
"writable": false,
"timestamp": "2026-05-23T18:06:38+00:00",
"value": 3181.0,
"strVal": "3181W",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47007",
"parameterName": "heating curve",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 6.0,
"strVal": "6",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 15.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47011",
"parameterName": "Offset",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": -10.0,
"maxValue": 10.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47015",
"parameterName": "climate system",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 70.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47020",
"parameterName": "flow line temp. at 30 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 15.0,
"strVal": "15°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47021",
"parameterName": "flow line temp. at 20 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 15.0,
"strVal": "15°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47022",
"parameterName": "flow line temp. at 10 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 26.0,
"strVal": "26°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47023",
"parameterName": "flow line temp. at 0 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 32.0,
"strVal": "32°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47024",
"parameterName": "flow line temp. at -10 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 35.0,
"strVal": "35°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47025",
"parameterName": "flow line temp. at -20 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 40.0,
"strVal": "40°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47026",
"parameterName": "flow line temp. at -30 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 45.0,
"strVal": "45°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 80.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47027",
"parameterName": "outdoor temp. point",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [],
"minValue": -40.0,
"maxValue": 30.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47028",
"parameterName": "change in curve",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [],
"minValue": -10.0,
"maxValue": 10.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47036",
"parameterName": "climate system",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 30.0,
"stepValue": 0.5,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47041",
"parameterName": "comfort mode",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 4.0,
"strVal": "4",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "0",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47050",
"parameterName": "activated",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 1.0,
"strVal": "1",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 1.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47051",
"parameterName": "period",
"parameterUnit": "days",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 15.0,
"strVal": "15days",
"smartHomeCategories": [],
"minValue": 1.0,
"maxValue": 90.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47137",
"parameterName": "op. mode",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:31+00:00",
"value": 0.0,
"strVal": "auto",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "auto",
"icon": ""
},
{
"value": "1",
"text": "manual",
"icon": ""
},
{
"value": "2",
"text": "add. heat only",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47206",
"parameterName": "start compressor",
"parameterUnit": "DM",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": -60.0,
"strVal": "-60DM",
"smartHomeCategories": [],
"minValue": -1000.0,
"maxValue": -30.0,
"stepValue": 10.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47209",
"parameterName": "diff. between additional steps",
"parameterUnit": "DM",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 100.0,
"strVal": "100DM",
"smartHomeCategories": [],
"minValue": 10.0,
"maxValue": 1000.0,
"stepValue": 10.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47212",
"parameterName": "set max electrical add.",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:31+00:00",
"value": 500.0,
"strVal": "5.0 kW",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "0.0 kW",
"icon": ""
},
{
"value": "50",
"text": "0.50 kW",
"icon": ""
},
{
"value": "100",
"text": "1.0 kW",
"icon": ""
},
{
"value": "150",
"text": "1.50 kW",
"icon": ""
},
{
"value": "200",
"text": "2.0 kW",
"icon": ""
},
{
"value": "250",
"text": "2.50 kW",
"icon": ""
},
{
"value": "300",
"text": "3.0 kW",
"icon": ""
},
{
"value": "350",
"text": "3.50 kW",
"icon": ""
},
{
"value": "400",
"text": "4.0 kW",
"icon": ""
},
{
"value": "450",
"text": "4.50 kW",
"icon": ""
},
{
"value": "500",
"text": "5.0 kW",
"icon": ""
},
{
"value": "550",
"text": "5.50 kW",
"icon": ""
},
{
"value": "600",
"text": "6.0 kW",
"icon": ""
},
{
"value": "650",
"text": "6.50 kW",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47335",
"parameterName": "time betw. switch heat/cool",
"parameterUnit": "hrs",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 2.0,
"strVal": "2hrs",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 48.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47336",
"parameterName": "heat at room under temp.",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 1.0,
"strVal": "1°C",
"smartHomeCategories": [],
"minValue": 0.5,
"maxValue": 10.0,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47337",
"parameterName": "cool at room over temp.",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 2.0,
"strVal": "2°C",
"smartHomeCategories": [],
"minValue": 0.5,
"maxValue": 10.0,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47340",
"parameterName": "cool/heat sensor",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 10.0,
"strVal": "RMU-BT50",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "none",
"icon": ""
},
{
"value": "2",
"text": "BT50",
"icon": ""
},
{
"value": "10",
"text": "RMU-BT50",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47374",
"parameterName": "start cooling",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 25.0,
"strVal": "25°C",
"smartHomeCategories": [],
"minValue": -20.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47375",
"parameterName": "stop heating",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -20.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47376",
"parameterName": "stop additional heat",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 2.0,
"strVal": "2°C",
"smartHomeCategories": [],
"minValue": -25.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47377",
"parameterName": "filtering time",
"parameterUnit": "hrs",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 2.0,
"strVal": "2hrs",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 48.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47394",
"parameterName": "control room sensor syst",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 1.0,
"strVal": "1",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 1.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47398",
"parameterName": "Room sensor set point value heating climate system 1",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 22.0,
"strVal": "22°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 35.0,
"stepValue": 0.5,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "47402",
"parameterName": "heating factor system",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 2.0,
"strVal": "2",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 6.0,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48072",
"parameterName": "start diff additional heat",
"parameterUnit": "DM",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 400.0,
"strVal": "400DM",
"smartHomeCategories": [],
"minValue": 100.0,
"maxValue": 2000.0,
"stepValue": 10.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48074",
"parameterName": "set pt value cool/heat sensor",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 21.0,
"strVal": "21°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48132",
"parameterName": "Hot water boost",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-04-02T15:19:09+00:00",
"value": 0.0,
"strVal": "Off",
"smartHomeCategories": [
"sh-hwBoost"
],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Off",
"icon": ""
},
{
"value": "4",
"text": "One-time incr.",
"icon": ""
},
{
"value": "1",
"text": "3 hr",
"icon": ""
},
{
"value": "2",
"text": "6 hr",
"icon": ""
},
{
"value": "3",
"text": "12 hr",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48177",
"parameterName": "climate system",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 18.0,
"strVal": "18°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 30.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48181",
"parameterName": "flow line temp. at 20 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48185",
"parameterName": "flow line temp. at 40 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48442",
"parameterName": "activated",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T13:11:03+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 1.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48731",
"parameterName": "cooling curve",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 9.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48739",
"parameterName": "Cooling offset climate system 1",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": -10.0,
"maxValue": 10.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48740",
"parameterName": "flow line temp. at 30 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48741",
"parameterName": "flow line temp. at 10 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48742",
"parameterName": "flow line temp. at 0 °C",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": -5.0,
"maxValue": 40.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48785",
"parameterName": "Room sensor set point value cooling climate system 1",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 26.0,
"strVal": "26°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 35.0,
"stepValue": 0.5,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "48793",
"parameterName": "cooling factor system",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 1.0,
"strVal": "1",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 6.0,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49715",
"parameterName": "climate system",
"parameterUnit": "°C",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 20.0,
"strVal": "20°C",
"smartHomeCategories": [],
"minValue": 5.0,
"maxValue": 30.0,
"stepValue": 0.5,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49903",
"parameterName": "alarm room sens cool",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 1.0,
"strVal": "1",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 1.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49909",
"parameterName": "start time",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": 0.0,
"maxValue": 23.0,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49993",
"parameterName": "Int elec add heat",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-23T18:06:01+00:00",
"value": 4.0,
"strVal": "Blocked",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Alarm",
"icon": ""
},
{
"value": "1",
"text": "Alarm",
"icon": ""
},
{
"value": "2",
"text": "Active",
"icon": ""
},
{
"value": "3",
"text": "Off",
"icon": ""
},
{
"value": "4",
"text": "Blocked",
"icon": ""
},
{
"value": "5",
"text": "Off",
"icon": ""
},
{
"value": "6",
"text": "Active",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49994",
"parameterName": "Priority",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T17:00:01+00:00",
"value": 20.0,
"strVal": "Hot water",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "10",
"text": "Off",
"icon": ""
},
{
"value": "20",
"text": "Hot water",
"icon": ""
},
{
"value": "30",
"text": "Heating",
"icon": ""
},
{
"value": "40",
"text": "Pool",
"icon": ""
},
{
"value": "41",
"text": "Pool 2",
"icon": ""
},
{
"value": "50",
"text": "Transfer",
"icon": ""
},
{
"value": "60",
"text": "Cooling",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "49995",
"parameterName": "Pump: Heating medium (GP1)",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T08:09:14+00:00",
"value": 1.0,
"strVal": "On",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Off",
"icon": ""
},
{
"value": "1",
"text": "On",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50004",
"parameterName": "Temporary lux",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "off",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "off",
"icon": ""
},
{
"value": "1",
"text": "on",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50095",
"parameterName": "status:",
"parameterUnit": "min",
"writable": false,
"timestamp": "2026-05-24T17:00:33+00:00",
"value": 15004.0,
"strVal": "15004min",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "15000",
"text": "Starting",
"icon": ""
},
{
"value": "15001",
"text": "Operating",
"icon": ""
},
{
"value": "15002",
"text": "Stopping",
"icon": ""
},
{
"value": "15003",
"text": "Off",
"icon": ""
},
{
"value": "15004",
"text": "Hot water",
"icon": ""
},
{
"value": "15005",
"text": "Heating",
"icon": ""
},
{
"value": "15006",
"text": "Pool",
"icon": ""
},
{
"value": "15007",
"text": "Cooling",
"icon": ""
},
{
"value": "15008",
"text": "Transfer",
"icon": ""
},
{
"value": "10480",
"text": "incomp. hp",
"icon": ""
},
{
"value": "10065",
"text": "Comm.fault In",
"icon": ""
},
{
"value": "10066",
"text": "Communication fault with PCA Input.",
"icon": ""
},
{
"value": "10067",
"text": "Communication fault with PCA Input.",
"icon": ""
},
{
"value": "10068",
"text": "Com.flt Base",
"icon": ""
},
{
"value": "10069",
"text": "Communication fault with PCA Base.",
"icon": ""
},
{
"value": "10070",
"text": "Communication fault with PCA Base.",
"icon": ""
},
{
"value": "10162",
"text": "Sens flt:BT18",
"icon": ""
},
{
"value": "15971",
"text": "incomp. inv.",
"icon": ""
},
{
"value": "10177",
"text": "Sens flt:BT14",
"icon": ""
},
{
"value": "10071",
"text": "HP alarm",
"icon": ""
},
{
"value": "10072",
"text": "High pressure alarm",
"icon": ""
},
{
"value": "10073",
"text": "High pressure alarm",
"icon": ""
},
{
"value": "10074",
"text": "LP alarm",
"icon": ""
},
{
"value": "10075",
"text": "Low pressure alarm",
"icon": ""
},
{
"value": "10076",
"text": "Low pressure alarm",
"icon": ""
},
{
"value": "10077",
"text": "Comm.flt MC",
"icon": ""
},
{
"value": "10078",
"text": "Comm.flt with PCA Motor Controller",
"icon": ""
},
{
"value": "10079",
"text": "Communication fault with PCA Motor Controller.",
"icon": ""
},
{
"value": "10080",
"text": "MP alarm",
"icon": ""
},
{
"value": "10081",
"text": "Motor protection alarm",
"icon": ""
},
{
"value": "10082",
"text": "Motor protection alarm",
"icon": ""
},
{
"value": "10083",
"text": "Sensor flt:BT1",
"icon": ""
},
{
"value": "10084",
"text": "Sensor fault: BT1 outdoor sensor",
"icon": ""
},
{
"value": "10085",
"text": "Sensor fault: BT1 outdoor sensor",
"icon": ""
},
{
"value": "10086",
"text": "Sensor flt:BT2",
"icon": ""
},
{
"value": "10087",
"text": "Sensor fault: BT2 flow line sensor 1",
"icon": ""
},
{
"value": "10088",
"text": "Sensor fault: BT2 flow line sensor 1",
"icon": ""
},
{
"value": "10089",
"text": "Sens flt:BT12",
"icon": ""
},
{
"value": "10090",
"text": "Sensor fault: BT12 condenser out",
"icon": ""
},
{
"value": "10091",
"text": "Sensor fault: BT12 condenser out",
"icon": ""
},
{
"value": "10092",
"text": "Sensor flt:BT3",
"icon": ""
},
{
"value": "10095",
"text": "Sensor flt:BT6",
"icon": ""
},
{
"value": "10154",
"text": "internal electrical addition",
"icon": ""
},
{
"value": "10183",
"text": "L exh.temp",
"icon": ""
},
{
"value": "10203",
"text": "Sensor flt:BT7",
"icon": ""
},
{
"value": "10187",
"text": "Defrosting",
"icon": ""
},
{
"value": "15117",
"text": "blocked",
"icon": ""
},
{
"value": "16528",
"text": "Inverter fault",
"icon": ""
},
{
"value": "10068",
"text": "Com.flt Base",
"icon": ""
},
{
"value": "10311",
"text": "Inverter I",
"icon": ""
},
{
"value": "10314",
"text": "Inverter II",
"icon": ""
},
{
"value": "10317",
"text": "Inverter III",
"icon": ""
},
{
"value": "10110",
"text": "Hot gas alarm",
"icon": ""
},
{
"value": "10116",
"text": "TB alarm",
"icon": ""
},
{
"value": "10122",
"text": "Hi cond. out",
"icon": ""
},
{
"value": "10276",
"text": "Err: BT63",
"icon": ""
},
{
"value": "10293",
"text": "serial no",
"icon": ""
},
{
"value": "10296",
"text": "software",
"icon": ""
},
{
"value": "11176",
"text": "comm.err hp",
"icon": ""
},
{
"value": "15117",
"text": "blocked",
"icon": ""
},
{
"value": "15629",
"text": "ext control",
"icon": ""
},
{
"value": "15701",
"text": "Preheat",
"icon": ""
},
{
"value": "15966",
"text": "Pres.alarm",
"icon": ""
},
{
"value": "15971",
"text": "incomp. inv.",
"icon": ""
},
{
"value": "16537",
"text": "Soft-start flt",
"icon": ""
},
{
"value": "16659",
"text": "Acc. block.",
"icon": ""
},
{
"value": "15468",
"text": "initiating",
"icon": ""
},
{
"value": "11165",
"text": "pool 2",
"icon": ""
},
{
"value": "11174",
"text": "com.err.slave",
"icon": ""
},
{
"value": "15985",
"text": "Com.flt GP12",
"icon": ""
},
{
"value": "16541",
"text": "not docked",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50113",
"parameterName": "status:",
"parameterUnit": "kW",
"writable": false,
"timestamp": "2026-05-23T18:06:03+00:00",
"value": 1512.0,
"strVal": "1512kW",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [
{
"value": "15000",
"text": "Starting",
"icon": ""
},
{
"value": "15001",
"text": "Operating",
"icon": ""
},
{
"value": "15002",
"text": "Stopping",
"icon": ""
},
{
"value": "15003",
"text": "Off",
"icon": ""
},
{
"value": "15004",
"text": "Hot water",
"icon": ""
},
{
"value": "15005",
"text": "Heating",
"icon": ""
},
{
"value": "15006",
"text": "Pool",
"icon": ""
},
{
"value": "15007",
"text": "Cooling",
"icon": ""
},
{
"value": "15008",
"text": "Transfer",
"icon": ""
},
{
"value": "10480",
"text": "incomp. hp",
"icon": ""
},
{
"value": "10065",
"text": "Comm.fault In",
"icon": ""
},
{
"value": "10066",
"text": "Communication fault with PCA Input.",
"icon": ""
},
{
"value": "10067",
"text": "Communication fault with PCA Input.",
"icon": ""
},
{
"value": "10068",
"text": "Com.flt Base",
"icon": ""
},
{
"value": "10069",
"text": "Communication fault with PCA Base.",
"icon": ""
},
{
"value": "10070",
"text": "Communication fault with PCA Base.",
"icon": ""
},
{
"value": "10162",
"text": "Sens flt:BT18",
"icon": ""
},
{
"value": "15971",
"text": "incomp. inv.",
"icon": ""
},
{
"value": "10177",
"text": "Sens flt:BT14",
"icon": ""
},
{
"value": "10071",
"text": "HP alarm",
"icon": ""
},
{
"value": "10072",
"text": "High pressure alarm",
"icon": ""
},
{
"value": "10073",
"text": "High pressure alarm",
"icon": ""
},
{
"value": "10074",
"text": "LP alarm",
"icon": ""
},
{
"value": "10075",
"text": "Low pressure alarm",
"icon": ""
},
{
"value": "10076",
"text": "Low pressure alarm",
"icon": ""
},
{
"value": "10077",
"text": "Comm.flt MC",
"icon": ""
},
{
"value": "10078",
"text": "Comm.flt with PCA Motor Controller",
"icon": ""
},
{
"value": "10079",
"text": "Communication fault with PCA Motor Controller.",
"icon": ""
},
{
"value": "10080",
"text": "MP alarm",
"icon": ""
},
{
"value": "10081",
"text": "Motor protection alarm",
"icon": ""
},
{
"value": "10082",
"text": "Motor protection alarm",
"icon": ""
},
{
"value": "10083",
"text": "Sensor flt:BT1",
"icon": ""
},
{
"value": "10084",
"text": "Sensor fault: BT1 outdoor sensor",
"icon": ""
},
{
"value": "10085",
"text": "Sensor fault: BT1 outdoor sensor",
"icon": ""
},
{
"value": "10086",
"text": "Sensor flt:BT2",
"icon": ""
},
{
"value": "10087",
"text": "Sensor fault: BT2 flow line sensor 1",
"icon": ""
},
{
"value": "10088",
"text": "Sensor fault: BT2 flow line sensor 1",
"icon": ""
},
{
"value": "10089",
"text": "Sens flt:BT12",
"icon": ""
},
{
"value": "10090",
"text": "Sensor fault: BT12 condenser out",
"icon": ""
},
{
"value": "10091",
"text": "Sensor fault: BT12 condenser out",
"icon": ""
},
{
"value": "10092",
"text": "Sensor flt:BT3",
"icon": ""
},
{
"value": "10095",
"text": "Sensor flt:BT6",
"icon": ""
},
{
"value": "10154",
"text": "internal electrical addition",
"icon": ""
},
{
"value": "10183",
"text": "L exh.temp",
"icon": ""
},
{
"value": "10203",
"text": "Sensor flt:BT7",
"icon": ""
},
{
"value": "10187",
"text": "Defrosting",
"icon": ""
},
{
"value": "15117",
"text": "blocked",
"icon": ""
},
{
"value": "16528",
"text": "Inverter fault",
"icon": ""
},
{
"value": "10068",
"text": "Com.flt Base",
"icon": ""
},
{
"value": "10311",
"text": "Inverter I",
"icon": ""
},
{
"value": "10314",
"text": "Inverter II",
"icon": ""
},
{
"value": "10317",
"text": "Inverter III",
"icon": ""
},
{
"value": "10110",
"text": "Hot gas alarm",
"icon": ""
},
{
"value": "10116",
"text": "TB alarm",
"icon": ""
},
{
"value": "10122",
"text": "Hi cond. out",
"icon": ""
},
{
"value": "10276",
"text": "Err: BT63",
"icon": ""
},
{
"value": "10293",
"text": "serial no",
"icon": ""
},
{
"value": "10296",
"text": "software",
"icon": ""
},
{
"value": "11176",
"text": "comm.err hp",
"icon": ""
},
{
"value": "15117",
"text": "blocked",
"icon": ""
},
{
"value": "15629",
"text": "ext control",
"icon": ""
},
{
"value": "15701",
"text": "Preheat",
"icon": ""
},
{
"value": "15966",
"text": "Pres.alarm",
"icon": ""
},
{
"value": "15971",
"text": "incomp. inv.",
"icon": ""
},
{
"value": "16537",
"text": "Soft-start flt",
"icon": ""
},
{
"value": "16659",
"text": "Acc. block.",
"icon": ""
},
{
"value": "15468",
"text": "initiating",
"icon": ""
},
{
"value": "11165",
"text": "pool 2",
"icon": ""
},
{
"value": "11174",
"text": "com.err.slave",
"icon": ""
},
{
"value": "15985",
"text": "Com.flt GP12",
"icon": ""
},
{
"value": "16541",
"text": "not docked",
"icon": ""
}
],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50203",
"parameterName": "Pump: Brine (GP2)",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-24T08:09:13+00:00",
"value": 1.0,
"strVal": "On",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "Off",
"icon": ""
},
{
"value": "1",
"text": "On",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50225",
"parameterName": "Current temperature system 1",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": -32768.0,
"strVal": "-32768°C",
"smartHomeCategories": [
"sh-indoorTempOverride"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50233",
"parameterName": "Set point value temp system 1, heat",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": -32768.0,
"strVal": "-32768°C",
"smartHomeCategories": [
"sh-indoorSpHeatOverride"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50241",
"parameterName": "Set point value temp system 1, cooling",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "0°C",
"smartHomeCategories": [
"sh-indoorSpCoolOverride"
],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50249",
"parameterName": "Next periodic increase: 27 . 05 . 2026",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-05-12T17:17:37+00:00",
"value": 3.0,
"strVal": "3",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50320",
"parameterName": "Smart Control",
"parameterUnit": "",
"writable": true,
"timestamp": "2026-01-26T12:46:28+00:00",
"value": 0.0,
"strVal": "off",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [
{
"value": "0",
"text": "off",
"icon": ""
},
{
"value": "1",
"text": "on",
"icon": ""
}
],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50325",
"parameterName": "Hot water temp.",
"parameterUnit": "°C",
"writable": false,
"timestamp": "2026-05-24T17:15:16+00:00",
"value": 49.0,
"strVal": "49°C",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 0.1,
"enumValues": [],
"scaleValue": "0.1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "50345",
"parameterName": "Hot water amount",
"parameterUnit": "min",
"writable": false,
"timestamp": "2026-05-24T17:15:00+00:00",
"value": 19.0,
"strVal": "19min",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
},
{
"category": "F1255-6 R PC",
"parameterId": "65535",
"parameterName": "Text not found: id[], fw[nibe-e10], lang[en-US]",
"parameterUnit": "",
"writable": false,
"timestamp": "2026-01-26T12:46:27+00:00",
"value": 0.0,
"strVal": "0",
"smartHomeCategories": [],
"minValue": null,
"maxValue": null,
"stepValue": 1.0,
"enumValues": [],
"scaleValue": "1",
"zoneId": null
}
]